Pass Through CSSD Autoclave System designed for efficient steam sterilization with separate loading and unloading sides, supporting controlled and hygienic CSSD workflow.

Speak to Specialist
METALLURGY AISI 316L SS
AUTOMATION PLC / HMI
COMPLIANCE IQ / OQ Validated
Pass-Through CSSD Autoclave System
PROXES METALLURGICAL STAMP

PRODUCT OVERVIEW

Pass Through CSSD Autoclave System designed for efficient steam sterilization with separate loading and unloading sides, supporting controlled and hygienic CSSD workflow.

The Pass Through CSSD Autoclave System is designed for hospitals, Central Sterile Supply Departments and healthcare facilities requiring controlled one-way material flow between contaminated and sterile areas. The pass-through configuration provides access from both sides of the sterilizer, helping separate loading and unloading operations and reducing unnecessary movement between zones.

The system uses high-pressure saturated steam for reliable sterilization of compatible medical instruments, surgical equipment, textiles and healthcare materials. PLC-based automation with touchscreen HMI provides controlled monitoring of sterilization parameters and programmable operating cycles. Safety interlocks, controlled door operation and process monitoring support safe and consistent CSSD operation.
Quality & Testing Protocol Each Pass Through CSSD Autoclave System can undergo factory testing including chamber pressure testing, leakage inspection, temperature and pressure verification, door operation and safety-interlock checks, sterilization cycle performance testing and functional inspection before dispatch. Validation documentation and IQ/OQ/PQ support can be provided as applicable to the supplied configuration.

KEY FEATURES

Core technical highlights that deliver precision control, uptime reliability, and patient safety.

01

Interlocked Pass-Through Barrier

Doors cannot be opened simultaneously, preventing dirty-to-clean air transference.

02

Flush Cleanroom Panel Mounting

Recessed stainless steel wall architecture for seamless sanitary room integration.

03

Pass Through Configuration

Dual-side access supports controlled material movement between loading and unloading zones.

04

CSSD Workflow Integration

Designed to support separation of contaminated and sterile areas within CSSD operations.

05

PLC Based Automation

Automated control of sterilization cycles and process parameters through a programmable control system.

06

High-Pressure Steam Sterilization

Uses controlled saturated steam for effective sterilization of compatible healthcare materials.

07

Programmable Sterilization Cycles

Configured operating cycles can be selected according to the application and sterilization load.

08

Process Monitoring

Continuous monitoring of critical sterilization parameters helps support consistent cycle operation.

09

Customized Configuration

Chamber size, door arrangement, loading system and other configurations can be customized according to project requirements.

010

Stainless Steel Construction

Robust stainless steel construction designed for demanding healthcare and CSSD environments.

TECHNICAL SPECIFICATIONS

Comprehensive engineering matrix and utility operational parameters.

Barrier Architecture

Door Configuration Double-Door Interlocked Pass-Through Mechanism
Mounting Interface Flush-Mount Stainless Steel Cleanroom Partition Trim

Metallurgy & Safety

Chamber Material AISI 316L Mirror Polish Stainless Steel
Door Locking Radial Multi-Arm Spoke Pressure Flange
Gauges Independent Chamber and Jacket Analog Gauges

Chamber & Construction

Equipment Type Pass Through CSSD Autoclave System
Chamber Construction Stainless Steel
Chamber Configuration Horizontal / Pass Through
Door Configuration Dual Door
Loading Side Contaminated / Unsterile Area
Unloading Side Sterile Area
Door Operation Automatic / Controlled
Insulation Thermal Insulation
Construction Heavy-Duty Healthcare/CSSD Design

Process Control & Automation

Controller PLC Based Control
User Interface Touchscreen HMI
Cycle Control Automatic Programmable
Parameter Monitoring Temperature & Pressure
Data Management Cycle Monitoring / Data Storage as configured